Refurbished Olympus Flexible Endoscopes

Refurbished Ethicon GEN 11 Generator

The Ethicon GEN11 is an electrosurgical generator that is simple and easy to use. The Ethicon Generator comes with a high-resolution touchscreen display that can be seen clearly from a variety of angles. At the same time, the generator can recognize when instruments are connected automatically...
Read More

Need more information or have a question?

Refurbished Ethicon GEN 11 Generator
Refurbished Ethicon GEN 11 Generator Refurbished Ethicon GEN 11 Generator Refurbished Ethicon GEN 11 Generator Refurbished Ethicon GEN 11 Generator Refurbished Ethicon GEN 11 Generator

The Ethicon GEN11 is an electrosurgical generator that is simple and easy to use. The Ethicon Generator comes with a high-resolution touchscreen display that can be seen clearly from a variety of angles. At the same time, the generator can recognize when instruments are connected automatically The GEN11 is powered by radio frequencies and is usually used in laparoscopic and gynecological surgeries. The Ethicon generator can support Harmonic Ultrasonic and Enseal Advanced Bipolar devices.

  • Universal connector and automatic instrument recognition.

  • Touchscreen for easy setup and operation.

  • High-resolution display with wider viewing angles.

  • Compact design takes up less space in the OR.

  • Software updates are available via USB memory stick.

Genique Medcrop offers Refurbished Ethicon Gen 11 Generator Systems up to 50% below OEM prices with the same service and warranty as new. The Ethicon System is not only technically refurbished but also cosmetically refurbished to make it work and look new. 

When the refurbishing process starts the Ethicon Gen 11 Generator is carefully inspected and tested by our in-house biomedical engineers who are highly skilled and certified to work on Generators. If necessary, parts are replaced to make sure that all aspects of the pump are functioning properly. Once everything is in working order, the unit is calibrated back to the original engineering manufacturer’s specifications. This ensures that the unit is working the same way that it originally left the manufacturer. 

After the Ethicon Gen 11 Generator system is working like new it undergoes a special cosmetic restoration process. The Ethicon system is cleaned, minor scratches and dents are repaired, it’s painted, and new decals are replaced if necessary. After this strenuous refurbishing process, the unit functions and looks like new. 

Genique Medcrop is ISO 13485 certified and ensures that the best quality is given to all capital medical equipment that they sell. Before the Ethicon Gen 11 Generator is labeled patient-ready and packed up for shipment, it goes through one last quality control test that makes sure all aspects are again working as they should. If you are looking to buy a refurbished Ethicon Gen 11 Generator. Whatsapp on 8930767729.

Ethicon GEN11 Generator Specifications

Dimensions (Generator)

  • Height: 7.5 in (13.6 cm)

  • Width: 14.8 in (35.5 cm)

  • Depth: 13.7 in (35 cm)

  • Weight: 13 lbs (5.9 kg)

Dimensions (Cart)

  • Height: 37.5 in (95.3 cm)

  • Width: 22.1 in (56.2 cm)

  • Depth: 18.9 in (48 cm)

  • Weight: 37 lbs (16.8 kg)

Dimensions (Footswitch)

  • Height: 4.1 in (10.4 cm)

  • Width: 13.45 in (34.2 cm)

  • Depth: 7.5 in (19 cm)

  • Weight: 8 lbs (3.6 kg)

Enseal Output

  • Bipolar, no neutral electrode required

  • 100 VAC RMS maximum

  • 135 watts maximum (rated load 15 ohms, unless otherwise specified in the instrument IFU)

  • 300 – 490 kHz (330 kHz, unless otherwise specified in instrument IFU)

Harmonic Output

  • 150 VAC RMS maximum (Unless otherwise specified in the instrument IFU)

  • 35 watts continuous (Unless otherwise specified in the instrument IFU)

  • 30 – 80 kHz (55.5 kHz unless otherwise marked in instrument IFU

Power

  • Main Input: 100–240 V, 50/60 Hz, 500 VA

  • Main Fuses: T5AL 250 V (Time-delay, 5 Amp, glass body, 5x20mm package size, quantity: 2)

Ambient Operating Conditions

  • Temperature: 59°F–80.6°F, 15°C–27°C

  • Humidity: 30%–75% non-condensing

  • Atmospheric Pressure Range: 700 hPa–1060 hPa

Transport and Storage Conditions

  • Temperature: -31°F–129.2°F, -35°C–+54°C

  • Humidity: 10%–95% non-condensing

  • Atmospheric Pressure Range: 700 hPa–1060 hPa

Protections / Classifications

  • Degree of Protection Against Electric Shock: Type CF applied part consisting of the Harmonic or Enseal instruments

  • Class of Protection Against Electric Shock: Class 1

  • Ingress Protection G11 Enclosure: IP21

  • Ingress Protection G11 Fotswitch: IP68



Brand

Ethicon

Ambient Operating Humidity

30%-75% non-condensing

Ambient Atmospheric Pressure Range

700 hPa-1060 hPa

Ambient Operating Temperature

59 DegreeF-80.6 DegreeF,15 DegreeC-27 DegreeC

Main Fuses

T5AL 250 V (Time-delay,5 Amp,glass body,5x20mm package size,quantity: 2)

Main Input:

100-240 V,50/60 Hz,500 VA

Model No

GEN-11

Review

Get in Touch

pioneering a new era of Healthcare Excellence

  • Instant pricing & lead-time options
  • Support from technical manufacturing experts
  • Lorem, ipsum dolor sit amet consectetur adipisicing elit. Tempore, dolore.