Refurbished Olympus Flexible Endoscopes
The Ethicon 300 ultraprecision harmonic scalpel utilizes ultrasonic energy to enable hemostatic cutting and coagulation of soft tissue. The Ethicon Harmonic Generator 300 consists of an ultrasonic generator, an optional footswitch, an optional hand-switching adaptor, and an option handpiece. This...
Read More
The Ethicon 300 ultraprecision harmonic scalpel utilizes ultrasonic energy to enable hemostatic cutting and coagulation of soft tissue. The Ethicon Harmonic Generator 300 consists of an ultrasonic generator, an optional footswitch, an optional hand-switching adaptor, and an option handpiece. This generator is for soft tissue incision when bleeding control and minimum thermal injury are desired. It can be used as an adjunct to or substitute for electrosurgery, lasers, and steel scalpels.
Indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired
Utilizes energy to enable hemostatic cutting and/or coagulation of soft tissue
5 power levels
Genique Medcrop offers Refurbished Ethicon 300 Harmonic Scalpel Systems up to 50% below OEM prices with the same service and warranty as new. This harmonic scalpel is not only technically refurbished but also cosmetically refurbished to make it work and look new. When the refurbishing process starts on the Ethicon 300 Harmonic Scalpel it is carefully inspected and tested by our in-house biomedical engineers who are highly skilled and certified to work on harmonic scalpels.
If necessary, parts are replaced to make sure that all aspects of the harmonic scalpel are functioning properly. Once everything is in working order, the harmonic scalpel is calibrated back to the original engineering manufacturer’s specifications. This ensures that the product is working the same way that it originally left the manufacturer.
After the Ethicon harmonic scalpel is working like new it undergoes a special cosmetic restoration process. The Ethicon 300 harmonic scalpel is cleaned, minor scratches and dents on the harmonic scalpel are repaired, it’s painted, and new decals are replaced if necessary. After this strenuous refurbishing process, the harmonic scalpel functions and looks like new. Genique Medcrop is ISO 13485 certified and ensures that the best quality is given to all capital medical equipment that they sell.
Before the Ethicon 300 harmonic scalpel is labeled patient-ready and packed up for shipment, it goes through one last quality control test that makes sure all aspects of the scalpel are again working as they should. If you are looking to buy a refurbished Ethicon 300 harmonic scalpel Please Contact us on 8930767729.
Height: 5.3 in (13 cm)
Width: 14.5 in (37 cm)
Depth: 15.2 in (39 cm)
Weight: 7.48 kg
Height: 37.3 in (95 cm)
Width: 17.7 in (45 cm)
Depth: 27.6 in (70 cm)
Voltage: 100-240 VAC
Frequency: 50/60 Hz
Current Consumption: 3 amp
Temperature 10°C to 40°C
Humidity: 10-90% non-condensing
Atmospheric Pressure Range: 700hPa-1060hPa
Temperature: -35°C to +54°C
Humidity: 10-95% non-condensing
Atmospheric Pressure Range: 700hPa-1060hPa
The system delivers two power levels: minimum (MIN) and maximum (MAX)
The minimal power level may be adjusted by the user from Level 1 to 5
The Maximum power level is always Level 5. With all instruments except the ball coagulator, use a higher generator power level for greater tissue-cutting speed and a lower generator power level for greater coagulation
The amount of energy delivered to the tissue and the resultant tissue effects are a function of many factors including the power level selected, instrument characteristics, grip force (when applicable), tissue tension, tissue type, pathology, and surgical technique
Ready, Standby, Increase/Decrease Power Level, Power, Volume,
Min, Max, Alarm Indicator, Hand Piece Receptacle, Hand Activation,
Test, and Graphic display, Footswitch Receptacles, Potential
Equalization Terminal, Fuses, Power Cord Receptacle.
The generator delivers audible tones to signal activation and alarm
states. The user may choose from three activation tone pitches. Upon
power-up, the system defaults to the last tone chosen.